(832) 899-4040

Water loss auditing and district metering

Non-revenue water is measured, not estimated. A clamp-on meter on a transmission main gives you the district inflow figure without a chamber, a bypass or a shutdown.

Ultraflux UF801-P
DN10–DN1000
0.4″1″2″6″12″24″40″
Nominal bore, log scale. Both meters clamp to the outside of the pipe — nothing is cut, drilled or shut down.

Temporary district metering

Permanent district meter installations are expensive and slow to permit. A rental clamp-on meter lets a utility establish whether a proposed district metered area is worth instrumenting before committing capital — measure inflow for a month, compare against billed consumption, and see whether the loss figure justifies the installation.

Night flow analysis

The classic leak indicator is minimum night flow. Between roughly 2 and 4 in the morning, legitimate demand in a residential district approaches zero, and whatever the meter still reads is largely loss. The UF801-P resolves velocity changes down to ±0.03 ft/s, which on a large main is a meaningful volume, and it logs at intervals fine enough to characterise the night minimum properly.

UF801-P transducers clamped to a fresh water transmission pipeline riser
A riser is often the only accessible point on a buried main. The sensors have to touch the pipe, so access dictates where you can measure.

Getting a usable reading on a buried main

  • You need access to the pipe. A valve chamber, an air valve pit or an exposed crossing. There is no way around this — the sensors must touch the pipe.
  • Cement-lined ductile iron is the common case and the common error. The lining thickness must be entered separately from the wall thickness. Getting it wrong shifts the effective bore and the flow figure with it.
  • Tuberculation. An old unlined cast iron main may have a significantly reduced effective bore. The meter cannot see this, and it will report flow based on the diameter you entered.
  • Wet chambers. Specify the IP68 sensor option. Chambers flood.

What a month of data gives you

Diurnal demand profile, weekday against weekend pattern, minimum night flow trend, and enough resolution to see whether a suspected leak is growing. That is the input to a water balance, and it is the difference between reporting a real loss percentage and reporting an assumption.

Can I run a water loss audit without installing a permanent meter?
Yes. A clamp-on meter logging on a transmission or distribution main for several weeks gives district inflow data without a permanent installation, which is often how utilities decide whether a permanent district meter is justified.
What pipe size can the rental meter handle?
The Ultraflux UF801-P measures pipe from DN10 up to DN1000, which covers most distribution mains.
How long can it log unattended?
Up to two months on internal power using the sleep function.
Does cement lining affect the measurement?
Yes, significantly. Lining thickness must be entered separately from the pipe wall thickness. Incorrect lining entry is the most common source of error on ductile iron water mains.

Get the meter on site this week

Request a rental quote(832) 899-4040